User manual for Kohler's Smart Seat C3-130, covering safety, installation, operation, and features like rear/front wash, heating, and deodorizing.
This is the user manual for the Kohler Smart Seat model C3-130 K-4107T-0 K-4107T-XP-0, a smart bidet seat with heated functions and adjustable water settings. It includes safety warnings, installation instructions, and operation details for features like rear and front wash, pulsate/oscillate modes, and temperature controls. The manual also covers maintenance, deodorizing, and energy-saving functions.
The device requires a dedicated 220V~, 50Hz, 10A circuit with GFCI or ELCB protection. It is designed for indoor use only and must not be exposed to water or excessive humidity. Safety precautions include not leaving children unattended near the unit and ensuring proper installation by professionals.
| Water Efficiency Grade | Level II |
|---|---|
| Min Water Pressure | 0.07MPa (dynamic pressure) |
| Max Water Pressure | 0.74MPa |
| Rated Voltage | 220V~, 50Hz |
| Rated Power | 1070W |
| Max Instantaneous Power | About 1600W |
| Product Outline Dimension | About 521mm x 435mm x 157mm |
| Weight | About 3.0kg |
| Inlet Water Temp | 1-35°C |
| Operation Environment | 1-40°C |
| Rear Wash | YES, adjustable |
| Front Wash | YES, adjustable |
| Water Flow (0.2MPa) | Max rear wash shall be no less than 500mL/min |
| Cleaning Water Temp | OFF, adjustable 5 dials (ambient temp, about 31-39°C) |
| Spray Time (Longest) | About 300s |
| Nozzle Adjustment | 5 Positions |
| Pulsate Cleaning | On/Off |
| Oscillating Cleaning | On/Off |
| Deodorizing Function | Yes, OFF, adjustable 5 dials |
| Thermal Fuse | Yes |
| Sanitary Antibacterial Material | Seat and Cover UV sanitize Yes |
| IoT Function | For K-4107T-XP-0 |
The minimum water pressure is 0.07MPa (dynamic pressure) and the maximum is 0.74MPa.
The rear wash function will stop automatically after 5 minutes of continuous flushing.
The maximum rear wash water flow shall be no less than 500mL/min.
Yes, the deodorizer feature is activated automatically when the user is seated and can be deactivated by pressing the STOP button.