This manual provides installation, configuration, and usage instructions for the K PCI-812 data acquisition card, covering analog input and digital I/O…
The K PCI-812 is a data acquisition interface card designed for use with 486, 586, Pentium, and Pentium II series computers. It features 16 single-ended analog input channels and 8-bit digital input/output channels, utilizing a 32-bit PCI bus for high-speed data transfer up to 132MB/s. The card supports various input ranges and gain settings, making it suitable for industrial process control and laboratory data acquisition systems.
The document details the hardware layout, including potentiometer adjustments for calibration, and explains the DB37 connector pin definitions for analog and digital signals. It also covers the installation of the driver software under Windows 95/98/NT/2000, providing step-by-step guides for hardware setup and software configuration. This manual is written in Chinese.
| Operating Temperature | 10°C to 40°C |
|---|
It is used for industrial control systems and laboratory data acquisition.
The A/D conversion speed is 10μs.
The input voltage range is 0V to 10V.
The A/D converter has a 12-bit resolution.