InterApp DESPONIA/DESPONIA plus butterfly valve installation and maintenance manual covering storage, mounting, bolting, testing and removal.
The InterApp DESPONIA and DESPONIA plus installation and maintenance manual gives procedures for storing, checking, installing and maintaining these butterfly valves. It states that the valves should be stored free from dust and humidity with the disc slightly open, and that installation must be carried out by qualified personnel according to the stated procedures.
The manual covers positioning in horizontal pipelines with the shaft horizontal, avoiding gaskets and grease, preparing flange facings, tightening stay-bolts and nuts, and using the bolting tables for PN 6, PN 10, PN 16 and ANSI 150 flanges. It also describes function testing, monthly operation, cleaning of the piping, removal, disposal and end-of-line mounting limitations.
| Body material | Ductile iron GGG 40 / EN-GJS-400-15 |
|---|---|
| Alternative body materials | carbon steel 1.0619 or stainless steel 1.4408 |
| Fluid and temperature | Only neutral liquids, temperature 10 - 80°C |
| Wafer-style flange compatibility | DIN PN10/16 or ANSI 150 flanges |
| Lug-type maximum working pressure without counter flange (DN 25 - 600) | PN 16 = 10 bar; PN 10 = 6 bar |
They should be stored free from dust and humidity, with the disc in a slightly open position until installation is completed.
No. The manual states never to use gaskets nor grease.
At least once monthly to help ensure reliable function.
No. Welding on the piping while the valve is between the flanges is inadmissible and would destroy the liner.