InterApp DESPONIA + DESPONIA plus Butterfly Valve Installation and Maintenance Manual

This manual provides installation, maintenance, operation, and storage instructions for InterApp DESPONIA and DESPONIA plus butterfly valves.


InterApp DESPONIA + DESPONIA plus Butterfly Valve Installation and Maintenance Manual - cover page
Brand
InterApp
Category
Other
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
1.7 MB
Published
08 November, 2026
Updated
08 November, 2026
MD5 checksum
1845CB4CE31AF695DA79F138FCCA5467

About this manual

This document serves as a guide for the proper installation, maintenance, and storage of InterApp DESPONIA and DESPONIA plus butterfly valves. It emphasizes that installation must be performed by qualified personnel according to state-of-the-art procedures to ensure safety and reliability. The manual outlines critical precautions regarding storage, positioning, and gasket usage to prevent premature failure or damage.

What's inside

  • Introduction
  • Storage
  • Precautions to be taken prior to installation
  • Check before installation
  • Installation
  • Bolting
  • Disposal
  • Function test
  • Cleansing of the piping
  • Removal

Specifications

Body materialDuctile iron GGG 40 / EN-GJS-400-15, carbon steel 1.0619 or stainless steel 1.4408
Nominal pressure PN 1610 bar
Nominal pressure PN 106 bar
Recommended operating intervalat least once monthly

Frequently asked questions

How should the valve be stored before installation?

The valve should be stored free from dust and humidity, with the disc in a slightly open position.

What type of gaskets should be used for installation?

Never use gaskets nor grease for the installation of these valves.

What is the recommended minimum distance for installing the valve after pipe fittings?

The valve should be installed a minimum of 5 x DN after pipe fittings.