IDEC product data table (as of June 2022) listing B10D, MTTFD, DC, Category, PL, PFHD and SIL values for its safety control modules.
This IDEC product data table, marked as current to June 2022, lists safety-related values for IDEC safety components. Each row gives the element/block/subsystem, the name and product type, and the values for B10D, MTTFD, DC, Category, PL, PFHD and SIL. Product types covered include safety relay modules (HR1S, HR2S, HR5S, HR6S), the FS1A safety controller, the EB3N explosion-proof safety barrier, light curtains (SE4B, SE4D, SE1L), safety switches (HS and HE types), emergency stop pushbutton switches, enable switches, grip switches and a laser scanner.
Notes in the table state that the MTTFD values are reference values according to ISO13849-1 Annex K and that maximum switching counts over the useful lifetime are given for DC-13, AC-1 and AC-15 loads. IDEC states that the contents are subject to change without notice. This manual is written in Japanese.
| Safety category and SIL (SE4D series) | Type 4 (EN61496-1/-2), Cat. 4/PL e (EN ISO13849-1), SIL3 (IEC61508) |
|---|---|
| Minimum detectable object (SE4D series) | φ25 mm |
| Detection width (SE4D-H12) | 230 mm |
| Detection width (SE4D-H96) | 1910 mm |
| Safety category and SIL (SE4B series) | Type 4 (EN61496-1), Cat. 4/PL e (EN ISO13849-1), SIL3 (EN62061) |
| Detection width (SE4B series) | 147-1617 mm |
| Category and SIL (SE1L series) | Type 3 (EN61496-1/-3), Cat. 3/PL d (EN ISO13849-1), SIL2 (IEC61508) |
| MTTFD (HR1S-AF) | 243 years |
| MTTFD (HR6S-AT, stop category 0) | 2400 years |
| Category and SIL (HR1S-ATE, Stop Cat.1) | Cat. 3/PL d (EN ISO13849-1), SIL2 (IEC61508) |
| Maximum switching count, useful lifetime (HR6S-AF) | DC-13, DC 24 V 1 A: 1,200,000 cycles / DC 24 V 3 A: 180,000 cycles |
| Maximum switching count, useful lifetime (HR6S-AB) | DC-13, DC 24 V 2 A: 50,000 cycles / AC-15, AC 250 V 3 A: 50,000 cycles |
| B10D (EB3N, Nop = 5500) | 100 cycles |
The SE4D is listed as Type 4 (EN61496-1/-2), Cat. 4/PL e (EN ISO13849-1) and SIL3 (IEC61508), with a minimum detectable object of φ25 mm.
The minimum detectable object is φ25 mm; detection widths are listed per model, from 230 mm on the SE4D-H12 up to 1910 mm on the SE4D-H96.
The table gives DC-13, DC 24 V 1 A: 1,200,000 cycles, DC 24 V 3 A: 180,000 cycles, AC-1, 250 V 4 A: 180,000 cycles, AC-15, 250 V 1 A: 70,000 cycles and 250 V 3 A: 39,000 cycles.
The HR6S-AT (stop category 0) is listed with an MTTFD of 2400 years, DC 99%, Category 4 and PL e.