Featured IDEC manuals

IDEC XW Series E-Stop User Manual
The XW Series E‑Stop switches feature IDEC’s patented Safe Break Action design, which guarantees that the normally‑closed contacts open even if the switch is damaged. The series offers up to four contacts in a compact 48.7 mm depth, with push‑lock, pull‑or‑turn reset options and optional illumination.
The manual covers key specifications, part numbers, mounting, wiring, terminal covers, and accessories such as nameplates and anti‑rotation rings, providing step‑by‑step instructions for safe installation and operation.
Covers: Overview · Key Features · Selection Guide · Part Numbers · Contact Ratings · Dimensions

IDEC Universal Photoelectric Sensors S15 Series Product Leaflet
The IDEC‑DATASENSOR catalog presents a full range of universal photoelectric sensors for industrial automation. It highlights the S15 series, a short‑body tubular sensor with a 40 mm housing, no sensitivity adjustment, and IP69K mechanical protection for harsh environments.
The document lists technical data, operating distances, power supply options, output types, connection methods, and housing materials for each sensor series, along with application notes for fork/slot, luminescence, contrast, distance and smart vision sensors.
Covers: Universal Photoelectric Sensors · Tubular Sensors · Miniature & Fiber Optic Sensors · Heavy Duty Sensors · Application Photoelectric Sensors · Fork/Slot Sensors

IDEC FL1E SmartRelay User Manual
This manual covers safety guidelines, qualified personnel requirements, and general information about the IDEC SmartRelay FL1E series. It explains the purpose of the document, new features, and the software tools needed for programming.
The guide is organized into eight chapters, including getting started, installation and wiring, programming, function blocks, configuration, memory and battery cartridges, software usage, and application examples. Technical data such as dimensions, power specifications, and input/output details are provided in the appendix.
Covers: Getting started with IDEC SmartRelay · IDEC SmartRelay installation and wiring · Programming IDEC SmartRelay · IDEC SmartRelay functions · Configuring IDEC SmartRelay · IDEC SmartRelay memory and battery cartridges

IDEC PS5R Power Supply User Manual
This manual covers the PS5R series of switching power supplies, including the 7.5 W, 15 W, 30 W, 50 W, 100 W, 120 W and 240 W variants. It details safety certifications (UL508, CSA, EN standards), environmental limits, and mounting options such as DIN‑rail or panel installation.
Technical data such as input voltage ranges, output power, efficiency, dimensions and protection features are listed, together with step‑by‑step installation, wiring diagrams, adjustment procedures, and guidelines for parallel or backup operation of multiple units. This manual is written in Chinese.
Covers: Safety Information · Technical Specifications · Installation Instructions · Wiring and Connection · Output Voltage Adjustment · Protection Features
Latest IDEC manuals
IDEC XW Series E-Stop User Manual
User Manual 10 pages · 1.3 MB · ENThe IDEC XW Series Emergency Stop manual provides safety features, specifications, wiring and installation instructions.
IDEC Universal Photoelectric Sensors S15 Series Product Leaflet
Product Leaflet 44 pages · 2.2 MB · ENA catalog of IDEC universal photoelectric sensors, focusing on the S15 series with specifications, optical functions and IP69K protection.
IDEC FL1E series SmartRelay owner's manual
This document covers the revision history of the IDEC SmartRelay product model B-1090(6). It includes information about sensor connections, compatibility, module structure, password settings, etc.
idec OPENNET CONTROLLER user manual
This document introduces the usage and functionality of the PID instruction, as well as its application example in temperature control. The PID instruction implements a PID algorithm with built-in auto tuning to determine PID parameters, and is designed for use with an analog I/O module for analog input reading and output control.
IDEC FC5A installation Manual
FC5A MicroSmart User Manual. Detailed introduction of the product function characteristics and usage methods.
IDEC FL1E SmartRelay User Manual
User Manual 352 pages · 6.4 MB · ENThe IDEC FL1E SmartRelay User Manual provides installation, wiring, programming, safety and technical information for the FL1E series.
IDEC PS5R Power Supply User Manual
User Manual 10 pages · 1.9 MB · ZHThe IDEC PS5R Power Supply User Manual provides specifications, installation, safety guidelines, and wiring instructions for the PS5R series.
idec Door Interlock Switches Manual
MICROSmart FC4A-SX5ES1 Network Server Unit User Manual
User Manual 4 pages · ZHThe MICROSmart FC4A-SX5ES1 Network Server Unit User Manual provides installation, configuration, and operation details for remote monitoring, email alerts…
IDEC PS3N Power Supply Manual
User Manual 10 pages · 2.3 MB · ZHThe IDEC PS3N manual provides specifications, installation instructions, safety guidelines, and wiring details for the PS3N switching power supplies.
IDEC EB3C Intrinsic Safety Relay Barrier User Manual
User Manual 17 pages · 3.6 MB · JAThe IDEC EB3C manual provides safety, installation, and wiring information for the intrinsic‑safety relay barrier.
IDEC FC5A programming controller Manual
IDEC LF1 LED Illumination unit Manual
IDEC WindO/I-NV2 Application program Downloader Manual
IDEC WindO/I-NV2 Application program Manual
User Manual 10 pages · 304 KB · ZHThe IDEC WindO/NV2 Pass-Through Tool Application Program Manual provides installation, configuration, and usage instructions for the tool.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in IDEC manuals
How many contacts can an XW series E‑Stop have?
The XW series can be configured with up to four contacts, including combinations of NC main contacts and NO monitor contacts.
What reset methods are available on XW E‑Stops?
The switches support push‑lock, pull‑or‑turn reset, and illuminated push‑ON reset options.
What is the housing length of the S15 sensors?
The S15 sensors have a housing length of only 40 mm.
From: IDEC Universal Photoelectric Sensors S15 Series Product Leaflet
What IP rating do the S15 sensors provide?
The S15 series is protected with an IP69K rating.
From: IDEC Universal Photoelectric Sensors S15 Series Product Leaflet
How many digital inputs does the FL1E module provide?
The FL1E module provides eight digital inputs.
What is the typical startup time for the FL1E SmartRelay?
The typical startup time at power‑up is 9 seconds.