Instruction manual for the George Fischer DIASTAR DN65-DN150 pneumatic diaphragm valve, covering installation, operation and diaphragm replacement.
The George Fischer DIASTAR is a pneumatically actuated diaphragm valve available in sizes DN65 to DN150. This instruction manual covers general features and valve design, installation information, technical data including control pressures and volumes, the Type PV93 solenoid pilot valve, operating modes FC, FO and DA, dimensions and weight, accessories, diaphragm replacement, the ER53 electrical feedback unit and spare parts.
The document states that the valve is safe to operate and requires little maintenance, and that flow direction and installation position are selectable. The actuator can use compressed air (oil-free) or inert gases, with fluids on request. Valve body materials listed are PVC-U, PP and PVDF; sealing diaphragms are EPDM or PTFE.
| Maximum allowable control pressure (FC mode) | 6 bar |
|---|---|
| Maximum allowable control pressure (FO/DA modes) | 5 bar |
| Control medium | Compressed air (oil-free), inert gases; fluids on request |
| Maximum control medium temperature | 40 °C |
| Actuator housing material | PP-GF |
| Stroke spindle material | Stainless steel |
| Sealing diaphragm material | EPDM or PTFE |
| Valve body material | PVC-U, PP or PVDF |
It can use oil-free compressed air or inert gases; control with liquids is available on request.
The maximum allowable control pressure is 6 bar in fail-safe-to-close mode.
It should be mounted as firmly as possible as a fixed point, using the threaded sleeves on the valve body.
The control medium temperature must not exceed 40 °C.