User manual for George Fischer DIASTAR diaphragm valves, covering installation, operation, technical specs, and materials for controlling neutral or…
This manual provides installation instructions and technical specifications for George Fischer DIASTAR diaphragm valves, designed for regulating neutral or aggressive media. It details valve materials, actuator types, pressure ratings, and torque requirements. The document includes diagrams for control and operating pressure, as well as dimensions and weights for various sizes.
Installation guidance emphasizes checking bolt torque before use and tightening bolts progressively in a cross pattern to ensure even load distribution on the diaphragm and valve body. The valves are available with EPDM or PTFE diaphragms and support fail-safe to close (FC), fail-safe to open (FO), or double-acting (DA) operation.
| Valve Body Materials | PVC, CPVC, polypropylene (PP-H), natural polypropylene (PP-n), PVDF |
|---|---|
| Actuator Material | All-plastic actuator made of PP-GF |
| Diaphragm Materials | EPDM or PTFE |
| Max. Torque for PTFE Diaphragms | Metric sizes: M6, M8, M12 |
The valve body is made of PVC, CPVC, polypropylene (PP-H), natural polypropylene (PP-n), or PVDF.
Tighten the bolts progressively in a cross pattern to the required torque with the valve open to ensure even load distribution.