The GEOKON 8020-38 Addressable Bus Converter Instruction Manual describes installation, USB and TTL connections, bit rate configuration, and specifications.
The GEOKON Model 8020-38 Addressable Bus Converter enables connections between GEOKON addressable sensor strings and systems such as personal computers, programmable logic controllers, readouts, and data loggers. It acts as a bridge between USB- or TTL-capable readers and GEOKON RS-485-enabled sensor strings, supporting bidirectional conversion between USB and RS-485 or TTL and RS-485. The device draws power from the 5 volt USB bus and generates a 12 volt supply for the RS-485 sensor string; with a TTL connection it requires an external 12 volt, 500 milliamp DC power supply.
Installation covers RS-485, TTL, and USB wire connections to the converter’s spring terminals, setting the bit rate (default 115,200 bps) via USB host software or terminal emulation, and configuring TTL inversion using the PCB switch. The manual also includes device specifications and instructions for installing USB drivers on Windows 10, 7, 8, and 8.1.
| Power Supply Input | USB: 5 Volts DC 500 mA; TTL: 12 Volts DC 500 mA |
|---|---|
| Power Supply Output | 12 Volts DC 200 mA (max) |
| Sleep Current | 500 uA Max (During USB Suspend) |
| Operating Current | 15 mA (max) |
| Operating Temperature | -40°C to 80°C |
| Communication Interface | RS-485 (half-duplex, two-wire differential); USB 1.0 to USB 3.1; 5V TTL |
| Baud Rate | 115200 (default), 57600, 38400, 19200, 14400, 9600 bps |
| Mechanical Housing | Polycase LP-11FMBT enclosure |
| Dimensions | 3.500”x2.545”x1.007” |
The default bit rate is 115,200 bits per second.
It draws power from the 5 volt USB bus.
No, a bit rate change cannot be done over a TTL connection; it must be set using a USB connection.
The operating temperature range is -40°C to 80°C.