GEOKON 8020-38 Addressable Bus Converter Instruction Manual

The GEOKON 8020-38 Addressable Bus Converter Instruction Manual describes installation, USB and TTL connections, bit rate configuration, and specifications.


GEOKON 8020-38 Addressable Bus Converter Instruction Manual - cover page
Brand
Geokon
Category
Converter
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.6 MB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
9843AE09B770B5BB3735A272B2DD3759

About this manual

The GEOKON Model 8020-38 Addressable Bus Converter enables connections between GEOKON addressable sensor strings and systems such as personal computers, programmable logic controllers, readouts, and data loggers. It acts as a bridge between USB- or TTL-capable readers and GEOKON RS-485-enabled sensor strings, supporting bidirectional conversion between USB and RS-485 or TTL and RS-485. The device draws power from the 5 volt USB bus and generates a 12 volt supply for the RS-485 sensor string; with a TTL connection it requires an external 12 volt, 500 milliamp DC power supply.

Installation covers RS-485, TTL, and USB wire connections to the converter’s spring terminals, setting the bit rate (default 115,200 bps) via USB host software or terminal emulation, and configuring TTL inversion using the PCB switch. The manual also includes device specifications and instructions for installing USB drivers on Windows 10, 7, 8, and 8.1.

What's inside

  • Introduction
  • Installation
  • RS-485 Cable Connection
  • TTL Connection
  • USB Connection
  • Setting Bit Rate
  • Using the Addressable Bus Converter
  • Specifications
  • Installing USB Drivers

Specifications

Power Supply InputUSB: 5 Volts DC 500 mA; TTL: 12 Volts DC 500 mA
Power Supply Output12 Volts DC 200 mA (max)
Sleep Current500 uA Max (During USB Suspend)
Operating Current15 mA (max)
Operating Temperature-40°C to 80°C
Communication InterfaceRS-485 (half-duplex, two-wire differential); USB 1.0 to USB 3.1; 5V TTL
Baud Rate115200 (default), 57600, 38400, 19200, 14400, 9600 bps
Mechanical HousingPolycase LP-11FMBT enclosure
Dimensions3.500”x2.545”x1.007”

Frequently asked questions

What is the default bit rate of the GEOKON 8020-38?

The default bit rate is 115,200 bits per second.

How is the converter powered when connected via USB?

It draws power from the 5 volt USB bus.

Can the bit rate be changed over a TTL connection?

No, a bit rate change cannot be done over a TTL connection; it must be set using a USB connection.

What is the operating temperature range?

The operating temperature range is -40°C to 80°C.

Download PDF (1.6 MB)

More Geokon Manuals