Geokon GK-4800/10/20 Earth Pressure Meter Installation and Operation Manual

GK-4800/10/20 Type Earth Pressure Meter Installation and Operation Manual


Geokon GK-4800/10/20 Earth Pressure Meter Installation and Operation Manual - cover page
Brand
Geokon
Category
sensor
Document type
User Manual
Language
Chinese
Pages
23
File format
PDF
File size
762 KB
Published
07 November, 2023
Updated
07 November, 2023
MD5 checksum
24B8855AABF3B62A1FEF83EFBCECBBE1

About this manual

The Geokon GK-4800/10/20 earth pressure meter is a vibrating-wire instrument used to measure soil stress or the pressure of soil structures. The manual explains its working principle, design, and structure, including the 4800 rectangular and circular models, the 4810 contact model, and the 4820 push-out model.

Installation topics include preliminary tests, pressure meter installation, cable installation, electrical noise interference, and initial readings. The manual then describes reading data with the GK-403 (BGK-408) portable readout, temperature measurement, pressure calculation, temperature and barometric pressure corrections, troubleshooting, and appendices with technical parameters and a semiconductor thermometer temperature formula. This manual is written in Chinese.

What's inside

  • Overview
  • Working Principle
  • Earth Pressure Meter Design
  • Earth Pressure Meter Structure
  • Installation
  • Cable Installation
  • Reading Data
  • Data Processing
  • Troubleshooting
  • Appendix A - Technical Parameters

Specifications

Measurement ranges (4800 rectangular/circular)350 kPa (50 psi); 700 kPa (100 psi); 1.5 MPa (250 psi); 3.5 MPa (500 psi); 5 MPa (750 psi); 7 MPa (1000 psi); 20 MPa (3000 psi)
Resolution0.025% FSR
Accuracy0.5% FSR
Linearity0.5% FSR standard; 0.1% FSR optional
Overrange200% FSR
Operating temperature range-30 to +70 °C
Pressure box material304 stainless steel
Coil resistance150 Ω
Cable2 twisted pairs (4-core tinned copper), 22 AWG
Weight (4800 rectangular / 4800 circular / 4810 / 4820)2.3 kg / 2.3 kg / 4.7 kg / 2.7 kg

Frequently asked questions

What does the earth pressure meter measure?

It is used to measure soil stress or the pressure of soil structures.

Which portable readout is described in the manual?

The manual covers operation of the GK-403 (BGK-408) portable readout.

What is the specified operating temperature range?

The operating temperature range is -30 to +70 °C.

What is the standard accuracy?

The standard accuracy is 0.5% FSR.

Download PDF (762 KB)