Geokon GK-4675 Static Level System Installation and Operation Manual

Geokon GK-4675 Static Level Installation and Operation Manual, mainly introduces the introduction, installation, reading, temperature change correction, troubleshooting and other content of the static level system.


Geokon GK-4675 Static Level System Installation and Operation Manual - cover page
Brand
Geokon
Category
Monitoring Equipment
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
319 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
009A231D91FC98C12E972B1306F7506F

About this manual

The Geokon GK-4675 is a high-precision liquid level system designed to measure relative settlement at multiple points. A series of sensor containers are joined by liquid lines, and the level in each container is measured by a precision vibrating-wire sensor fitted with a free float; vertical displacement at every point is referenced to one datum container whose movement is known or determined by other means.

The manual covers installation (mounting the reservoirs, connecting the liquid lines, filling the system, installing the sensors and connecting the vent tubes), taking readings with a GK-403 or BGK-408 readout on the "B" range, the settlement calculation formula with a worked four-point example, temperature correction of the vibrating-wire readings, and troubleshooting of coil resistance and cable faults. This manual is written in Chinese.

What's inside

  • Introduction
  • Installation
  • Mounting the reservoirs
  • Connecting the liquid lines
  • Filling the system
  • Installing the sensors
  • Connecting the vent tubes
  • Taking readings
  • Temperature correction
  • Troubleshooting

Specifications

Coil resistance180 ±10 Ω plus cable resistance
Cable resistance (standard 22 gauge copper wire)about 15 Ω per 300 m
Fill level at which filling is stoppedabout 10 cm below the reservoir opening
Readout instrumentGK-403 or BGK-408, "B" range
Mounting bolt diameter10 mm expansion bolts
Temperature correction coefficient0.0002 per °C of water temperature

Frequently asked questions

What readout instrument is used with the GK-4675 static level system?

Readings are taken with a GK-403 (or BGK-408) readout, with the instrument set to the "B" range.

What should the sensor coil resistance be?

The coil resistance should normally be 180 ±10 Ω plus the cable resistance.

What liquid is used to fill the system?

Pure water is used to fill the system; if the ambient temperature may drop below zero, a proportion of antifreeze is added to the water.

How is the level change of a container calculated?

ΔELx = (R1x − R0x)Gx − (R0Ref − R1Ref)GRef, where each sensor's coefficient G is taken from its calibration sheet.