Gefran 4B96 Position Force and Pressure Indicator User Manual

User manual for the Gefran 4B96 digital indicator with strain-gauge and potentiometer inputs, covering installation, configuration, and maintenance.


Gefran 4B96 Position Force and Pressure Indicator User Manual - cover page
Brand
GEFRAN
Category
Monitoring Equipment
Document type
User Manual
Language
English
Pages
20
File format
PDF
File size
299 KB
Published
17 November, 2026
Updated
17 November, 2026
MD5 checksum
2FB977778809068906835E902F794D33

About this manual

The Gefran 4B96 is a digital indicator designed for position, force, and pressure measurement using strain-gauge or potentiometer inputs. It features a single universal input supporting potentiometers (minimum 100 Ω), load cells (1.5–3.3 mV/V autoranging), and strain-gauge pressure probes (accuracy better than 0.2% full scale). The instrument provides sensor excitation voltages of 1.2 Vdc for potentiometers and 5 or 10 Vdc (max 120 mA) for strain gauges, and includes a serial interface for PC configuration via Winstrum software.

The front panel offers a red five-digit process variable display and three buttons for manual configuration, protected by a Lexan membrane rated IP65. Power supply accepts 100–240 Vac/dc. The manual details panel mounting, wiring, menu navigation, calibration (UCAL), hold and Eb functions, cleaning, jumper checks, troubleshooting, and order code information.

What's inside

  • Preliminary instructions
  • Installation and connection
  • Functions
  • Configuration and programming
  • Technical specifications
  • Maintenance
  • Technical-Commercial information

Specifications

Input typesPotentiometer (≥100 Ω), load cell (1.5–3.3 mV/V autoranging), strain-gauge pressure probe
Sensor excitation1.2 Vdc for potentiometer; 5 Vdc or 10 Vdc max 120 mA for strain-gauge
DisplayRed five-digit process variable display
Front panel protectionIP65 (Lexan membrane)
Configuration interfaceSerial line for PC configuration via Winstrum software
Power supply100–240 Vac/dc
Operating buttonsThree buttons for manual configuration/selection

Frequently asked questions

What sensor types can be connected to the 4B96 indicator?

The 4B96 accepts potentiometers (minimum 100 Ω), load cells with autoranging sensitivity from 1.5 to 3.3 mV/V, and strain-gauge pressure probes with accuracy better than 0.2% full scale.

What is the power supply voltage range for the 4B96?

The 4B96 operates on a 100–240 Vac/dc power supply.

What front panel protection rating does the 4B96 have?

The front panel is protected by a Lexan membrane that guarantees IP65 level protection.