This document introduces the features and characteristics of GEFRAN 40B96/40B48 digital display meters, alarm meters, and thyristor switch elements. The digital display meter is available in 96 and 48-grid formats, supports 24V to 240Vac power supply, has a maximum load of 3A, and has alarm function and relay output. The thyristor switch element is suitable for the 96-grid format with an output of 1, supports 11-27Vac/dc to 100-240Vac/dc power supply, has a maximum load of 3A, and has 3 breakpoints that can be set as alarm points.
The GEFRAN 40B96/40B48 is a microprocessor-based digital display meter designed for industrial control environments. It features a 1/16 DIN or 1/8 DIN format with a Lexan-protected panel, a 3-digit or 4-digit display, and three LED indicators for output status. The device supports various input signals from sensors, including strain gauges and potentiometers, with automatic sensitivity measurement and calibration capabilities. This manual is written in Chinese.
| Panel Protection | IP65 |
|---|---|
| Input Accuracy | 0.2%fs ±1 digit |
| Relay Output Rating | 5A/250V |
| Logic Output Voltage | 0 to 11Vdc |
| Analog Output Range | 4 to 20mA |
| Operating Temperature | 0...50°C |
| Storage Temperature | -20...70°C |
| Weight (48 format) | 160g |
| Weight (96 format) | 320g |
Yes, a programming tool with a Windows menu-driven configuration program is available for PC configuration.
The maximum load for the 4-20mA output is 1500 Ohms.
Standard is 100...240Vac/dc, and optional is 11...27Vac/dc.