Installation and operation guide for the ST75 and ST75V mass flow meters, covering serial number alignment, flow direction, specifications, and wiring.
This document serves as the installation and operation guide for the Fluid Components International ST75 and ST75V (Vortab) mass flow meters. It provides essential pre-installation information, including instructions for serial number alignment and flow direction verification to ensure the sensor and transmitter circuit are correctly paired and oriented.
| Accuracy | ST75: ±2% of reading, ±0.5% of full scale; ST75V: ±1% of reading, ±0.5% of full scale |
|---|---|
| Repeatability | ± 0.5% of reading |
| Operating Temperature Range | 0 to 140 °F [-18 to 60 °C] |
| Input Power (DC) | 18 VDC to 36 VDC |
| Input Power (AC) | 85 V AC to 265 V AC |
| Output Signals | (2) 4-20 mA user assignable; (1) 0-500 Hz pulse |
| Communication Port | RS232C standard |
FCI recommends a minimum of 20 diameters upstream and 10 pipe diameters downstream.
Removal is not recommended unless authorized by a factory technician as it can affect calibration.
Use a wrist band or heel strap with a 1 megohm resistor connected to ground.