Key facts
- Manuals
- 1
- Languages
- EN
- Last added
- 2026-10-03
Featured Fluid Components International manuals

Fluid Components International ST51A / ST75A / ST75AV Mass Flow Meters User Manual
The ST51A, ST75A and ST75AV are thermal‑dispersion mass flow meters for air and gas applications. The ST51A is an insertion type for 2"‑24" lines, the ST75A is an in‑line type for ¼"‑2" lines, and the ST75AV uses a Vortab in‑line element. All models provide mass flow, totalized flow and temperature readings via dual 4‑20 mA, pulse, HART and optional LCD display.
The manual covers safety instructions, wiring, installation of flow elements and remote enclosures, configuration of HART and Modbus communication, calibration, troubleshooting, and warranty information. Detailed tables list optional accessories, specifications, and wiring diagrams.
Covers: General · Installation · Operation · Maintenance · Troubleshooting · Specifications
Latest Fluid Components International manuals
Fluid Components International ST51A / ST75A / ST75AV Mass Flow Meters User Manual
User Manual 114 pages · 8.4 MB · ENUser manual with installation, operation, maintenance, safety and specifications for the ST51A, ST75A and ST75AV mass flow meters.
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Fluid Components International manuals
What temperature range can the ST51A flow meter operate in?
The ST51A operates from 0 °F (‑18 °C) up to 350 °F (177 °C).
From: Fluid Components International ST51A / ST75A / ST75AV Mass Flow Meters User Manual
What safety precautions are required for installation in hazardous areas?
Installation must be performed by qualified personnel, follow NEC/CEC wiring rules, use a circuit breaker or disconnect switch, and observe ESD precautions.
From: Fluid Components International ST51A / ST75A / ST75AV Mass Flow Meters User Manual