Component maintenance manual for the FCI PN 015838 Water Level & Temperature Monitoring System used in Canadair aircraft.
This document serves as a Component Maintenance Manual for the Fluid Components International (FCI) PN 015838 Water Level & Temperature Monitoring System, specifically designed for Canadair aircraft. It contains confidential technical data and proprietary information regarding the system's maintenance and troubleshooting.
The resistance is 272±8 ohms at 68°F (20°C).
The long 19.86 inch (504 mm) probe is used in the lavatory potable water tank.
No, the system is not field repairable other than the removal and replacement of the probes or the control unit enclosure.