This manual provides operation instructions for the Festo VPPL proportional pressure valve, covering installation, commissioning, and maintenance.
This document is the operation manual for the Festo VPPL proportional pressure valve. It describes the product's functions, structure, installation requirements, commissioning steps, operation modes, and maintenance procedures. The valve is designed for use in industrial automation applications for pressure regulation. This manual is written in German.
| Working Voltage | DC 21.6 ... 27.6 V |
|---|---|
| Adjustment Range | 0.02 ... 2 MPa |
| Standard Adjustment Accuracy | 2 % |
| Nominal Bore | 2.5 mm |
| Protection Class | IP65 |
The valve requires filtered, non-lubricated compressed air with a filtration accuracy of at least 40 μm.
The valve allows a maximum input pressure of 4 MPa (580 psi).
The maximum total leakage rate is less than 20 liters per hour.
The working medium temperature must not exceed 50 °C.