User manual for the EUCHNER GS...C1806 12 mm precision combination switch, covering installation, operation, maintenance, and technical specifications.
This user manual applies to all GS...C1806 12 mm precision combination switches, serving as the complete user information when combined with the "Safety Information and Maintenance" document and any provided datasheets. The device is designed for positioning and control applications in machinery and industrial systems, utilizing a plunger triggered by blocks that vary based on application requirements such as positioning accuracy and approach speed. This manual is written in Chinese.
| Housing Material | Cast aluminum, anodized |
|---|---|
| Plunger Material | Stainless steel |
| Protection Rating | IP67 |
| Mechanical Operating Cycle | 30x10^6 |
| Switching Frequency | 300 min^-1 |
| Operating Temperature | -5 ...+80 °C |
| Max Approach Speed (Roller R) | 80 m/min |
| Max Approach Speed (Roller B) | 120 m/min |
| Max Approach Speed (Circular W/Spherical K) | 10 m/min |
| Min Approach Speed | 0.01 m/min |
| Actuation Force | ≥ 20 N |
| Switch Elements | 1 NO + 1 NC contact |
| Switch Principle | Snap-action contact |
| Magnetic Hysteresis | 0.8 mm |
| Contact Material | Silver alloy, electrically bright gold |
| Wiring Method | Screw terminals |
| Rated Insulation Voltage | Ui = 250 V |
| Rated Impulse Withstand Voltage | Uimp = 2.5 kV |
| Category AC-12 | 250 V 8 A |
| Category AC-15 | 230 V 6 A |
| Category DC-13 | 24 V 6 A |
The user manual must be read together with the "Safety Information and Maintenance" document and any provided datasheets.
Installation and electrical connection work must be performed by authorized personnel.
No, the precision combination switch and trigger block must not be used as end stops.
The maximum approach speed for the Roller R (sliding bearing) plunger type is 80 m/min.