EUCHNER GS...C1806 12 mm Precision Combination Switch User Manual

User manual for the EUCHNER GS...C1806 12 mm precision combination switch, covering installation, operation, maintenance, and technical specifications.


EUCHNER GS...C1806 12 mm Precision Combination Switch User Manual - cover page
Brand
EUCHNER
Category
Industrial Robot
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
734 KB
Published
14 November, 2026
Updated
14 November, 2026
MD5 checksum
2B03DFB62522D4CEB633EB19319D57CB

About this manual

This user manual applies to all GS...C1806 12 mm precision combination switches, serving as the complete user information when combined with the "Safety Information and Maintenance" document and any provided datasheets. The device is designed for positioning and control applications in machinery and industrial systems, utilizing a plunger triggered by blocks that vary based on application requirements such as positioning accuracy and approach speed. This manual is written in Chinese.

What's inside

  • Scope of Application
  • Correct Use
  • Function
  • Switch Status
  • Installation
  • Electrical Connection
  • Functional Test
  • Inspection and Maintenance
  • Technical Data
  • Compliance Declaration

Specifications

Housing MaterialCast aluminum, anodized
Plunger MaterialStainless steel
Protection RatingIP67
Mechanical Operating Cycle30x10^6
Switching Frequency300 min^-1
Operating Temperature-5 ...+80 °C
Max Approach Speed (Roller R)80 m/min
Max Approach Speed (Roller B)120 m/min
Max Approach Speed (Circular W/Spherical K)10 m/min
Min Approach Speed0.01 m/min
Actuation Force≥ 20 N
Switch Elements1 NO + 1 NC contact
Switch PrincipleSnap-action contact
Magnetic Hysteresis0.8 mm
Contact MaterialSilver alloy, electrically bright gold
Wiring MethodScrew terminals
Rated Insulation VoltageUi = 250 V
Rated Impulse Withstand VoltageUimp = 2.5 kV
Category AC-12250 V 8 A
Category AC-15230 V 6 A
Category DC-1324 V 6 A

Frequently asked questions

What documents are required for complete user information?

The user manual must be read together with the "Safety Information and Maintenance" document and any provided datasheets.

Who is authorized to perform installation and electrical connections?

Installation and electrical connection work must be performed by authorized personnel.

Can the precision combination switch and trigger block be used as end stops?

No, the precision combination switch and trigger block must not be used as end stops.

What is the maximum approach speed for the Roller R plunger type?

The maximum approach speed for the Roller R (sliding bearing) plunger type is 80 m/min.