EUCHNER MGB-...-AP.../MGB-...-AR... Safety System Product Leaflet

EUCHNER MGB-...-AP.../MGB-...-AR... safety system configurations with spring-force locking, technical data, dimensions and accessories.


EUCHNER MGB-...-AP.../MGB-...-AR... Safety System Product Leaflet - cover page
Brand
EUCHNER
Category
Other products
Document type
Product Leaflet
Language
Spanish
Pages
5
File format
PDF
File size
1.4 MB
Published
13 November, 2026
Updated
13 November, 2026
MD5 checksum
1FA4AECFE90BAA9FDC0BB4499D503DA0

About this manual

EUCHNER MGB-...-AP.../MGB-...-AR... is a safety system with spring-force locking (MGB-L1-...) and four indicators or control elements. It supports series connection with other AR devices and is available with cable entry or connector, with integrated control elements and indicators.

The document lists order configurations, block diagrams and connection schemes, technical data, dimension drawings, a drilling template, and accessories and spare parts. Technical data include housing materials, weight, ambient temperature range, protection degree, locking force, voltages, currents, safety and monitoring outputs, reliability values, and control-element ratings. This manual is written in Spanish.

What's inside

  • Configuraciones con bloqueo
  • Tabla de pedido
  • Diagrama de bloques y esquemas de conexiones
  • Datos técnicos
  • Planos de dimensiones
  • Plantilla de taladros
  • Accesorios y repuestos
  • Módulos de la configuración

Specifications

Housing materialGlass-fiber reinforced plastic, nickel-plated zinc die casting, stainless steel
Weight0.75 (locking module)
Ambient temperature-20 to +55 °C at UB = 24 V DC
Protection degreeIP65 / IP54
Locking force2000 N
Service voltage24 V DC +10% / -15% (PELV)
Current consumption80 mA (all outputs without load)
Solenoid energized current350 mA
Safety outputsSemiconductor outputs, p-switching, short-circuit protected
Power-on test durationAR < 1000 / AP < 300 ps
Activation current per safety output1 to 200 mA
Utilization categoryCC-13, 24 V, 200 mA
Monitoring output loadMax. 50 mA
Overvoltage resistance1.5 kV
Switching frequency0.25 Hz
ReliabilityCategory 4, PL e
PFHd3.1 x 10^-9/h
Service life20 years
Control elements service voltage5 to 24 V
Control elements current1 to 100 mA
Control elements max switching power250 mW
LED supply24 V DC

Frequently asked questions

Can the MGB system be connected in series with other AR devices?

Yes, it can be connected in series with other AR devices such as CES-AR, CET-AR and CTP-AR.

What is the locking force?

The locking force F is 2000 N according to GS-ET-19.

Can the user choose the color of the pushbuttons?

Yes, the user can choose the desired color using the included color parts kit.