EUCHNER ESM-BA3.. Emergency Stop Safety Relay User Information

EUCHNER ESM-BA3.. emergency stop safety relay user information covering installation, electrical connection, starting behavior, maintenance, and technical data.


EUCHNER ESM-BA3.. Emergency Stop Safety Relay User Information - cover page
Brand
EUCHNER
Category
RELAY
Document type
User Manual
Language
English
Pages
6
File format
PDF
File size
1.4 MB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
14ACF0264F5C7D9229B6B393E4D7676E

About this manual

The EUCHNER ESM-BA3.. is an emergency stop safety relay with three safe relay outputs, one auxiliary contact, and single- or dual-channel operation. It is designed for safe isolation of safety circuits according to EN 60204-1 and can be used up to category 4, PL e according to EN ISO 13849-1.

The document covers correct use, electrical connection, installation, commissioning, starting behavior, applications, maintenance, fault handling, and technical data for the ESM-BA301, ESM-BA302, and ESM-BA303 variants.

What's inside

  • Correct Use
  • Features
  • Function
  • Electrical Connection
  • Installation
  • Safety Precautions
  • Commissioning Procedure
  • Applications
  • Maintenance
  • Techn. Data

Specifications

Operating voltageESM-BA301: AC/DC 24 V; ESM-BA302: AC 115 V; ESM-BA303: AC 230 V
Safety contacts3 NO contacts
Auxiliary contacts1 NC contact
Maximum switching voltageAC 250 V
Degree of protectionIP20
Temperature range-15°C to +40°C
Weightapprox. 230 g
MountingDIN rail according to EN 60715TH35
Line cross section0.14 - 2.5 mm²
Rated insulation voltage250 V

Frequently asked questions

What is the ESM-BA3.. used for?

It is a universal emergency stop safety switching device with three safe relay outputs for single- or dual-channel emergency stop circuits and guard monitoring.

What start behaviors are possible?

The ESM-BA3.. supports monitored manual start and automatic start.

How is the ESM-BA3.. mounted?

It is mounted on a 35 mm DIN rail according to DIN EN 60715 TH35, and it is intended for control cabinets with at least IP54 protection.

What maintenance does the ESM-BA3.. require?

It must be checked once per month for proper function and for signs of tampering or bypassing of the safety function; otherwise it is maintenance free if installed properly.

Download PDF (1.4 MB)