Esterline FLS402 programmable solid-state timer with two open-collector outputs, adjustable delay, and DC supply; datasheet lists timing, accuracy, and ratings.
The Esterline FLS402 is a programmable solid-state timer with two solid-state outputs (open collector). It can operate on operate, on release, or repeat cycle, with adjustable timing delay and a DC power supply.
The document provides the numbering system, mounting styles, terminal types, timing ranges, accuracy codes, and electrical, mechanical, and environmental characteristics.
| Output current (open collector) | 250 mA max |
|---|---|
| Contacts rated at | 0.25 A / 28 Vdc |
| Weight | 70 g max |
| Enclosure dimensions without hardware mounting | 26 x 25.7 x 26 mm max |
| Enclosure | Hermetically sealed, corrosion protected metal can |
| Contact arrangement | 2 solid-state outputs (open collector) |
| Operating voltage | 28 Vdc (18 to 32 Vdc) |
| Operating current (X1) | 15 mA max |
| Control input current for code D operating (X2) | 5 mA max at 28 Vdc |
| Dielectric strength | 1000 Vrms / 50 Hz |
| Insulation resistance | 100 MΩ |
| Sinusoidal vibration, 10-70 Hz | 3 mm DA |
| Sinusoidal vibration, 70-3000 Hz | 30 G |
| Mechanical shock | 50 G / 11 ms |
| Protection against abnormal surge voltage | +80 Vdc / 100 ms |
| Protection against damage by voltage spikes | ±600 Vdc / 10 µs |
| Temperature range code A | -55°C to +125°C |
| Temperature range code B | -40°C to +85°C |
| Timing range 1 | 0.1 to < 0.4 seconds |
| Timing range 2 | 0.4 to < 3.2 seconds |
| Timing range 3 | 3.2 to < 25 seconds |
| Timing range 4 | 25 to 625 seconds |
| Accuracy code 1 | ±3% fixed/adjustable; 1% resistor accuracy; 50 ppm/°C |
| Accuracy code 2 | ±5% fixed/adjustable; 2% resistor accuracy; 100 ppm/°C |
| Accuracy code 3 | ±10% fixed/adjustable; 5% resistor accuracy; 100 ppm/°C |
| Mounting styles | A, B, C, D, J |
| Terminal types | 1, 2, 4 |
| Applicable sockets | S402 |
28 Vdc (18 to 32 Vdc).
Two solid-state outputs (open collector).
250 mA max.
-55°C to +125°C.