Endress+Hauser Flexdip CYA112 Wastewater Assembly Technical Information

Endress+Hauser Flexdip CYA112 is a modular sensor assembly for open basins, channels and tanks with varying water levels.


Endress+Hauser Flexdip CYA112 Wastewater Assembly Technical Information - cover page
Brand
Endress+Hauser
Category
Other products
Document type
Product Leaflet
Language
English
Pages
16
File format
PDF
File size
655 KB
Published
23 November, 2026
Updated
23 November, 2026
MD5 checksum
0CAD9B10A8D5454ADA5F6C852A1F7C8C

About this manual

Flexdip CYA112 is a modular assembly system for sensors in open basins, channels and tanks. It is suitable for sensors with various connection threads, and a float assembly is available for varying water levels. The assembly is available in stainless steel or PVC versions, with immersion pipe lengths from 600 mm (23.6") to 3600 mm (142").

It can be installed in standard, chain, or floater configurations. A quick fastener supports fast installation and exchange of Memosens sensors, twist-free installation of fixed-cable sensors, and sensor alignment. Ambient temperature range is -20 to +60 °C (-4 to 140 °F), and process temperature range is 0 to 60 °C (32 to 140 °F).

What's inside

  • Function and system design
  • Measuring system
  • PVC version
  • Stainless steel version
  • Floater version
  • Quick fastener
  • Installation conditions
  • Environment
  • Mechanical construction
  • Product structure

Specifications

Assembly length range600 to 3600 mm (23.6" to 142")
Immersion pipe outer diameter40 mm (1.57")
Ambient temperature-20 to +60 °C (-4 to 140 °F)
Process temperature range0 to 60 °C (32 to 140 °F)
Process pressure rangeUnpressurized
Immersion pipe materialsStainless steel or PVC
Standard sensor adapter threadG 1
Floater immersion depthapprox. 600 mm (23.6")
Floater maximum stroke (600 mm pipe)approx. 400 mm (16")

Frequently asked questions

What installation configurations are available for the CYA112?

Standard, chain, and floater configurations.

What is the ambient temperature range?

-20 to +60 °C (-4 to 140 °F).

What is the maximum achievable length for the PVC version?

2400 mm (94.5").

What sensor thread does the standard adapter use?

G 1; other threads require an adapter.

Download PDF (655 KB)