Emerson DF Series self-operated pressure regulating valve (nitrogen sealing valve) manual covering specs, installation, operation, maintenance and parts.
The Emerson DF Series is a direct-acting micro-pressure regulating valve that uses the pressure of the flowing medium to drive its actuator and stabilize downstream pressure. It is intended for gas blanketing systems on containers and tanks in petroleum, chemical, pharmaceutical and food applications, and for media such as nitrogen and carbon dioxide.
The user manual covers the valve's main technical parameters, features, dimensions, structure and working principle, actuator and spring selection, flow curve, installation and operation, maintenance, and spare parts and parts lists. It lists body sizes DN 25 and DN 50, inlet pressure 0.1 to 1.0 MPa, outlet pressure 0.4 to 25 kPa, and a temperature range of -29 to 80°C. This manual is written in Chinese.
| Valve body size | DN 25 and DN 50 / 1 and 2 inches |
|---|---|
| Body design pressure | 1.6 MPa / 232 psig |
| Inlet pressure (P1) | 0.1 to 1.0 MPa / 14.5 to 145 psig |
| Outlet pressure (P2) | 0.4 to 25 kPa / 0.06 to 3.63 psig |
| Operating temperature range | -29 to 80°C / -20 to 176°F |
| Leakage class | ANSI Class VI |
| Body material | WCC, CF8M |
| Trim material | 316 stainless steel |
| Diaphragm and seals | Nitrile (NBR) |
| Flow coefficient | 1-inch body: CV = 14; 2-inch body: CV = 48 |
| Flow characteristic | Quick opening |
Nitrogen, carbon dioxide and other gases used for blanketing protection or requiring micro-pressure control.
The outlet pressure range is 0.4 to 25 kPa (0.06 to 3.63 psig).
Every 3 to 6 months is recommended, depending on gas quality and use.
Release the pressure inside the valve body before maintenance.