Installation and use manual for Elkay Soft Sides refrigerated fountains models ECRSP8C*A, ECRSPVR8C*A, and LCRSP8C*A, covering plumbing, electrical…
This manual provides installation and operating instructions for Elkay Soft Sides® refrigerated fountains with FLEXI-GUARD®. It covers models ECRSP8C*A, ECRSPVR8C*A, and LCRSP8C*A, detailing plumbing connections, electrical wiring, quick-connect fitting operation, and stream height adjustment. The document includes safety warnings about grounding and electrolysis, and specifies supply pressure limits of 20–105 PSI.
The installation steps guide the installer through mounting the remote chiller, making water supply connections, routing tubing, securing panels, and performing final checks. Troubleshooting advice addresses mineral deposits on the orifice, stream regulation, and quick-connect fitting actuation. A parts list with part numbers is provided for replacement ordering.
| Supply line pressure range | 20–105 PSI |
|---|---|
| Factory stream height setting | 35 PSI |
| Chiller water inlet tube size | 1/4" O.D. copper tube |
| Building water supply tube size | 3/8" O.D. unplated copper tube |
| Drain tube size | 1-1/4" OD |
The fountain is designed to operate on supply line pressures between 20 and 105 PSI.
Adjust the screw on the regulator using a small screwdriver through the hole in the push button; clockwise raises the stream, counter-clockwise lowers it.
The chiller inlet and outlet use 1/4" O.D. tubing, while the building supply connection uses 3/8" O.D. unplated copper tube.
All service must be performed by an authorized service person.