This manual is the owner's manual for Elkay EDFPVR320RC drinking fountain. It introduces the product's features and characteristics, as well as installation, use and maintenance methods.
This manual provides step-by-step installation instructions for the Elkay EDFPVR320RC drinking fountain, including plumbing connections, electrical grounding precautions, and mounting details. It also covers routine maintenance, cleaning methods, and troubleshooting for mineral deposits or flow issues. All service must be performed by an authorized technician, and plastic drain fittings are required to prevent electrolysis.
The document includes detailed diagrams for internal and external trap installations, part lists, and specifications for water pressure (20–105 PSI). Cleaning is simple with non-abrasive agents, and periodic waxing helps maintain the fountain’s finish.
| Water Pressure Range | 20-105 PSI |
|---|
Use plastic drain fittings to electrically isolate the fountain from the building plumbing system.
Adjust the regulator screw using a small screwdriver through the push button hole; clockwise raises height, counter-clockwise lowers it.
Use a soft sponge, cloth, or non-abrasive aerosol foam cleaner. Rinse thoroughly and polish with a soft cloth.