Elkay EDFPVR320RFPK Freeze Resistant Marblyte Fountain Installation Guide

This manual describes the installation method of Elkay EDFPVR320RFPK Freeze Resistant Marblyte Fountain, including the grounding of water and electric lines and the insulation measures of the fountain.


Elkay EDFPVR320RFPK Freeze Resistant Marblyte Fountain Installation Guide - cover page
Brand
Elkay
Document type
Installation Guide
Language
English
Pages
7
File format
PDF
File size
215 KB
Published
21 October, 2023
Updated
21 October, 2023
MD5 checksum
87D422D598FB06611BFA532D5B9EE069

About this manual

This guide provides step-by-step instructions for installing the Elkay EDFPVR320RFPK freeze-resistant Marblyte fountain. It covers wall mounting, connecting water and drain lines, adjusting the operating cable, and ensuring proper electrical grounding to prevent electrolysis. The document also includes maintenance tips and troubleshooting for common issues like mineral deposits or valve malfunctions.

The fountain requires a heated interior space for the freeze-resistant package, with a minimum temperature of 50°F (10°C). Dimensions and hole layouts are provided for compliance with ADA and ANSI standards. All service must be performed by an authorized technician, and the document includes a parts list and contact information for Elkay support.

What's inside

  • Installation Steps
  • Mounting Dimensions
  • Electrical Grounding
  • Water Line Connections
  • Cable Adjustment
  • Maintenance
  • Troubleshooting
  • Parts List

Specifications

Minimum Interior Temperature50° F (10° C)
Stream Height Adjustment35 PSI factory setting
Water Supply Tube3/8" O.D. unplated copper tube

Frequently asked questions

What is the minimum temperature required for the interior heated area?

The room temperature must be 50° F (10° C) or higher.

How do I adjust the stream height?

Adjust the screw on the regulator in the freeze-resistant package; clockwise raises height, counter-clockwise lowers it.

What materials should I use for drain fittings to prevent electrolysis?

Use plastic drain fittings to electrically isolate the fountain from the building plumbing system.