This manual describes the installation method of Elkay EDFPVR320RFPK Freeze Resistant Marblyte Fountain, including the grounding of water and electric lines and the insulation measures of the fountain.
This guide provides step-by-step instructions for installing the Elkay EDFPVR320RFPK freeze-resistant Marblyte fountain. It covers wall mounting, connecting water and drain lines, adjusting the operating cable, and ensuring proper electrical grounding to prevent electrolysis. The document also includes maintenance tips and troubleshooting for common issues like mineral deposits or valve malfunctions.
The fountain requires a heated interior space for the freeze-resistant package, with a minimum temperature of 50°F (10°C). Dimensions and hole layouts are provided for compliance with ADA and ANSI standards. All service must be performed by an authorized technician, and the document includes a parts list and contact information for Elkay support.
| Minimum Interior Temperature | 50° F (10° C) |
|---|---|
| Stream Height Adjustment | 35 PSI factory setting |
| Water Supply Tube | 3/8" O.D. unplated copper tube |
The room temperature must be 50° F (10° C) or higher.
Adjust the screw on the regulator in the freeze-resistant package; clockwise raises height, counter-clockwise lowers it.
Use plastic drain fittings to electrically isolate the fountain from the building plumbing system.