Elcometer 236 DC Holiday Detector Operating Instructions

Operating instructions for the Elcometer 236 DC Holiday Detector, covering safe high-voltage coating flaw inspection, setup, use, troubleshooting, and…


Elcometer 236 DC Holiday Detector Operating Instructions - cover page
Brand
Elcometer
Category
Other products
Document type
User Manual
Language
English
Pages
48
File format
PDF
File size
2 MB
Published
21 November, 2026
Updated
21 November, 2026
Model
236
MD5 checksum
6D6160C1B26E1B03457CC52A22162CD5

About this manual

The Elcometer 236 DC Holiday Detector locates flaws in non-conducting coatings on conducting substrates, including coatings up to 7 mm thick. It applies high DC voltage through a probe and connects to the substrate via a high voltage return lead; a spark, audible alarm, and visual alarm indicate a flaw.

The manual covers safe use, standards and test methods, setup, operation, static electricity, current monitoring, voltage and sensitivity settings, probe selection, troubleshooting, maintenance, storage, spares, technical specification, and related equipment. Safety guidance includes not using the detector in combustible atmospheres, in rain or damp conditions, or while the charger is connected; the battery is supplied discharged and must be charged before first use.

What's inside

  • About this holiday detector
  • Working safely
  • Holiday detection
  • Standards and test methods
  • Getting started
  • Using the Holiday Detector
  • Static electricity
  • Using the current monitoring function
  • Setting the test voltage and sensitivity
  • Probe selection

Specifications

High voltage at probeUp to 30,000 volts
Maximum coating thicknessUp to 7 mm (275 mils)
Minimum coating thicknessAt least 200 µm
Preferred coating thicknessOver 500 µm
Probe speed (ASTM D 4787)0.3 m/s (1 ft/s) maximum
RF emissions at 3 mApproximately 60 dBµV/m from 30 MHz to 1000 MHz
Distance from sensitive electronic equipmentNot within 30 m

Frequently asked questions

What coating thickness can the Elcometer 236 detect flaws in?

It can test coatings up to 7 mm (275 mils) thick and requires coatings at least 200 µm thick, preferably over 500 µm thick.

Can the detector be used while the battery is charging?

No, it must not be used for high voltage testing while connected to the mains electricity supply for battery charging.

What safety precautions should be followed?

Wear rubber gloves, work well clear of other personnel, and do not use the equipment in combustible or flammable atmospheres.

Why is the battery supplied discharged?

For safety and reliability, the detector is supplied with the battery discharged and it must be recharged before first use.

Download PDF (2 MB)

More Elcometer Manuals


View all Elcometer manuals →