User manual for Elcometer Series 8 pull-off adhesion gauge for testing coating adhesion on concrete substrates.
This manual details how to test coating adhesion on concrete using a 50mm dolly. It covers preparation, cutting, adhesive application, and force measurement. The Elcometer 510 model offers automatic pull rate control and digital data storage via USB or Bluetooth. Failure modes are recorded as percentages for each layer.
A 50mm diameter dolly is most commonly used for consistent and reliable results at low pull-off values.
Failure mode is recorded as an estimated percentage to the nearest 10%, using codes to denote the layer or layers in which the failure occurred.