Elcometer 3570 Micrometric Film Applicator and 3580 Casting Knife Film Applicator User Guide

Elcometer 3570 Micrometric Film Applicator and 3580 Casting Knife Film Applicator are simple but effective instruments for applying a uniform and reproducible film of coating to a substrate.


Elcometer 3570 Micrometric Film Applicator and 3580 Casting Knife Film Applicator User Guide - cover page
Brand
Elcometer
Category
Other
Document type
User Manual
Language
English
Pages
56
File format
PDF
File size
4.2 MB
Published
25 November, 2023
Updated
25 November, 2023
MD5 checksum
EDAF78B381110428A55FBE03458D4AD1

About this manual

The Elcometer 3570 Micrometric Film Applicator and Elcometer 3580 Casting Knife Film Applicator are instruments for applying a uniform and reproducible film of coating to a substrate. The Elcometer 3570 is made of anodised aluminium with a reservoir and bevelled blade, and is intended for manual application of high viscosity fluids onto relatively firm substrates. The Elcometer 3580 has a bevelled blade and extended sides, and is intended for manually applying thick layers on solid and flat surfaces.

The guide covers box contents, setting the blade gap, the application procedure, wet film thickness, care and maintenance, spares and accessories, warranty and technical specifications. It states that the Elcometer 3570 gap is adjustable in 1 µm intervals from 0 to 1 mm using a micrometric screw, and the Elcometer 3580 film thickness is adjustable in 10 µm steps from 0 to 6 mm using two integrated micrometric screws.

What's inside

  • Overview
  • Box Contents
  • Test Procedure
  • Setting the Blade Gap
  • Application Procedure
  • Wet Film Thickness
  • Care & Maintenance
  • Spares & Accessories
  • Warranty Statement
  • Technical Specification

Specifications

Elcometer 3570 film thickness range0 to 1 mm, adjustable in 1 µm intervals
Elcometer 3580 film thickness range0 to 6 mm, adjustable in 10 µm steps
Accuracy±0.01 mm
Elcometer 3570 materialAnodised aluminium
Elcometer 3580 materialAnodised aluminium
Elcometer 3570 total widthFilm width plus 36 mm
Elcometer 3580 total widthFilm width plus 15 mm
StandardASTM D 823-E
Recommended viscosityGreater than 2000 cP

Frequently asked questions

Where should the Elcometer 3570 be placed when setting the blade gap?

It should be placed on a flat and horizontal base such as glass or a vacuum table.

What micrometer setting gives a 50 µm gap on the Elcometer 3570?

Set the micrometer to 0.5 mm; the gap value must be multiplied by 10.

How should the film applicator be cleaned after use?

Clean it with a suitable solvent, then ensure all materials are removed and the applicator is dry. Do not use very aggressive solvents, wire brushes, metal scrapers or metal files.

What warranty applies to the Elcometer 3570 and 3580?

They are supplied with a one year warranty against manufacturing defects, excluding contamination and wear.

Download PDF (4.2 MB)

More Elcometer Manuals


View all Elcometer manuals →