Datasheet for EDAC 516 Series Rack and Panel Connectors covering specifications, contact options, covers, hardware and polarizing codes.
The EDAC 516 Series Rack and Panel Connectors datasheet presents connector features and specifications. It lists 0.150” (3.81mm) contact spacing, 0.130” (3.30mm) or 0.150” (3.81mm) row spacing, and plug and receptacle sizes with 20, 38, 56, 90 and 120 contacts. Insulator materials include diallyl phthalate, thermoplastic polyester or polycarbonate, with copper alloy contacts and gold plating over nickel.
The document explains the example part number and code options for contacts, styles and materials, covers and hardware. It also covers crimp characteristics, ordering code notes and polarizing codes, including 288 mating combinations and standard plug code PG1G1 and receptacle code RS1S1.
| Insulator Material | Diallyl Phthalate, Thermoplastic Polyester or Polycarbonate |
|---|---|
| Contact Material | Copper Alloy |
| Contact Plating | Gold Plating over Nickel over entire contact |
| Current Rating | 8.5 amps |
| Contact Resistance | 10 milliohms maximum |
| Dielectric Withstanding Voltage | 2000 V AC rms at sea level |
| Insulation Resistance | 5000 megaohms minimum |
| Operating Temperature | -40°C to +125°C (Diallyl Phthalate Only) |
| Operating Temperature | -40°C to +105°C |
| Insertion & Withdrawal Force | 2 to 16 oz (0.56 to 4.45N) per contact position |
| Contact Spacing | 0.150” (3.81mm) |
| Row Spacing | 0.130” (3.30mm) or 0.150” (3.81mm) |
| Contact Sizes | 20, 38, 56, 90 and 120 |
| Compliance | RoHS Compliant & UL Certified |
The series offers plug and receptacle connectors in 20, 38, 56, 90 and 120 contact sizes.
The current rating is 8.5 amps.
-40°C to +125°C.
They accommodate 28AWG to 18AWG solid or stranded conductors.