This manual provides installation, operation, cleaning instructions and technical specifications for the e 835 and e 835 S dynamic microphones.
The document serves as an instruction manual for the e 835 and e 835 S microphones. It covers product overview details such as components like the sound inlet basket, XLR-3 connector, and on/off switch specific to the e 835 S model.
| Transducer principle | dynamic |
|---|---|
| Frequency response | 40 - 16,000 Hz |
| Pick-up pattern | cardioid |
| Sensitivity (free field, no load) | 2.7 mV/Pa |
| Nominal impedance (at 1 kHz) | 350 Ω |
| Min. terminating impedance | 1 kΩ |
| Connector | XLR-3 |
| Temperature range | 0 °C to +40 °C |
| Dimensions | ⌀ 48 x 180 mm |
| Weight | 330 g |
Only hold the radio microphone by its body to avoid changing the pick-up pattern.
Covering the microphone head changes the pick-up pattern and consequently the sound.
Position them in the angle area of the highest cancellation of the microphone (approx. 180°) to prevent feedback.