Installation, operation, and maintenance manual for Donaldson DFOE3, DFOE4, and DFOE6 dust collectors used for airborne particulate collection.
The Donaldson DFOE3, DFOE4, and DFOE6 dust collectors are designed for the highly efficient and continuous on-line collection of airborne dust and particulate. The system uses filter elements to clean air before it is returned to the plant environment, employing an automatic sequential cleaning cycle using compressed air pulses to remove collected dust.
This manual provides detailed instructions for the installation of compressed air and electrical connections, start-up procedures, regular service tasks such as dust removal and filter replacement, and troubleshooting guidelines for common operational issues.
| Compressed air pressure | 6 bar |
|---|---|
| Maximum system requirements | 45 Nliters per pulse at 6 bar |
| Filter element replacement interval | 2000—4000 hours |
It is recommended to empty the dustbin on a regular basis, specifically when it is 1/2 full, to avoid poor collector performance.
The filter elements must be changed when airflow is low or the differential pressure is too high and an alarm occurs.
The compressed air supply must be oil and moisture free, and the line must include a shut-off valve, a filter/water separator with automatic condense drain, and a pressure regulator with gage.