TD486 Dust Collectors Installation, Operation, Service and Replacement Parts Information.
This manual covers the Donaldson TD486 Dust Collector, which is used for collection of airborne dust and particulate in manufacturing operations and air pollution applications. It includes installation, operation, service, and replacement parts information for the unit.
Contents include introduction, operational explanation, hoppers, installation, electrical installation, service, element replacement, replacement parts, limited warranty, and multiple parts drawings for cabinet assembly and optional equipment packs.
| Filter element dimensions | 7-7/8 O.D., 3-9/16" I.D., by 16" long |
|---|---|
| Hopper discharge clearance | 48" |
| Hopper angle | at least 59° |
| Timer input voltage | 105-135 VAC, 50-60 Hz |
| Timer output rating | 200 watts maximum load per output |
| Timer pulse width | 100 milliseconds |
| Solenoid valve rating | 120 VAC, 14.6 watts each |
It is used for collection of airborne dust and particulate.
The pulse is factory-set at 100 milliseconds.
It is 48 inches.
They are rated at 120 VAC and 14.6 watts each.