Dimetix AE-0505 application note describes using laser distance sensors for automated roll diameter and width measurement in paper and textile mills.
The Dimetix AE-0505 application example describes automated diameter and width measurement for paper and textile mills. A pair of Dimetix laser distance sensors are mounted opposing each other to measure roll width; both distance readings are added together based on a known separation distance, which the document calls a differential measurement. Sensors mounted overhead measure roll diameter from a known position and calibration offset, with the rolls resting in a shallow V roller assembly.
The document lists non-contact visible eye-safe laser measurement, spacing for material transport and foot traffic, enough measurement range to avoid adjustment for different roll sizes, PLC or PC data acquisition, and maintenance-free operation with no moving parts or string cables to break.
| Measurement type | Non-contact visible eye-safe laser measurement |
|---|---|
| Width measurement method | Differential measurement using two opposing sensors; both distance readings are added together |
| Diameter measurement method | Overhead sensor uses known position and calibration offset |
| Data acquisition | PLC or PC |
A pair of Dimetix laser distance sensors are mounted opposing each other, and both distance measurements are added together to determine roll width based on a known separation distance.
Dimetix laser sensors mounted overhead measure diameter based on a known position and calibration offset.
The application example is for paper and textile mills.
The document lists string potentiometers, transducers, ultrasonic sensors, and manual tape measure readings as alternatives.