This document describes how to use the D-Series laser distance sensor, including installation, preparation, and measurement.
This document provides step-by-step instructions for the initial setup and operation of Dimetix D-Series laser distance sensors. It covers safety precautions, installation notes, and the preparation process using the Laser Sensor Utility software on a PC.
| Operating Voltage | 12...30 VDC |
|---|---|
| Standard Baud Rate | 19200 Baud, 7 Bit, Parity even |
| Normal Measurement Rate | 20 Hz |
| Fast Measurement Rate | 250 Hz (DPE) / 50 Hz |
| Precise Measurement Rate | 10 Hz |
| Moving Target Measurement Rate | 250 Hz (DPE) / 50 Hz |
For short range (0...40 m), a white matt surface or a Dimetix orange reflective target is recommended.
The maximum length of the filter is given with 32 entries.