Dimetix Laser Distance Sensors DLS/FLS Series Technical Reference Manual

This document is a technical reference manual for laser distance sensors DLS-C30, DLS-C15, DLS-CH30, DLS-CH15, FLS-C30, FLS-C10, FLS-CH30, FLS-CH10. It provides information about the components, effectiveness, measurement range, and methods to prevent erroneous measurement results. It also includes sections on instrument settings, installation, technical specifications, electronic components, physical dimensions, factory settings, command settings, accessories, and safety instructions.


Dimetix Laser Distance Sensors DLS/FLS Series Technical Reference Manual - cover page
Brand
Dimetix
Category
Industrial Robot
Document type
User Manual
Language
Chinese
Pages
42
File format
PDF
File size
720 KB
Published
19 October, 2022
Updated
28 September, 2023
MD5 checksum
DE75CD1112E2DBBC75CF065CD0B6E33B

About this manual

This document is the Technical Reference Manual for Dimetix laser distance sensors, covering the DLS-C(H) and FLS-C(H) series. It details product identification, components, and effective software versions required for operation.

The manual covers instrument setup including connection methods and control modes (Controlled vs. Automatic). It provides instructions for installation, assembly, and wiring, along with a comprehensive list of technical parameters such as measurement accuracy and range. Additionally, it includes sections on the electronic parts, factory settings, and a detailed command reference for configuration. This manual is written in Chinese.

What's inside

  • Introduction
  • Instrument Setup
  • Installation
  • Technical Parameters
  • Electronic Parts
  • Factory Settings
  • Command Settings
  • Accessories
  • Safety Instructions
  • Maintenance

Specifications

Measurement Range0.05-500m
Measurement Frequency (DLS-C)6Hz
Measurement Frequency (FLS-C)25Hz
Standard Accuracy1.5mm / 3.0mm
Supply Voltage9...30V
Laser ClassClass II (<0.95mW)
Protection RatingIP65

Frequently asked questions

What are the supported interface software versions?

The manual is valid for interface software version 0100 or newer.

What is the maximum number of modules connectable via a single RS422 line?

A single RS422 line can connect up to 10 modules.

What happens if the aiming angle is very small on a smooth surface?

The laser may be reflected away, resulting in a weak signal and a 255 error message.

Download PDF (720 KB)

More Dimetix Manuals


View all Dimetix manuals →