Danfoss ERC 112 Electronic Refrigeration Controller User Guide

Danfoss ERC 112 electronic refrigeration controller user guide for OEM programming, with specifications, connections, and code numbers.


Danfoss ERC 112 Electronic Refrigeration Controller User Guide - cover page
Brand
Danfoss
Category
Other Electronics
Document type
Programming Manual
Language
English
Pages
30
File format
PDF
File size
4.4 MB
Published
09 November, 2026
Updated
09 November, 2026
Model
ERC 112
MD5 checksum
13280FA09A37FF77B1A084F1CFAAD89C

About this manual

The Danfoss ERC 112 is an electronic refrigeration controller with an LED display developed for bottle coolers and commercial fridges and freezers. This guide is intended for OEMs and technicians for programming the controller and is not intended as a guide for end users.

It covers product features, application advantages, approvals, typical applications, dimensions, technical specifications, input and output connections, and code numbers for controllers, sensors, and accessories.

What's inside

  • Application Advantages
  • Approvals
  • Introduction
  • Typical application
  • Product overview
  • Quick programming
  • Dimensions
  • Technical specs
  • Connections
  • Code numbers

Specifications

Power supply100 - 240 V AC
Average power consumption0.7 W
Inputs5 inputs: 4 analogue (digital), 1 digital
Compressor relay output120 V AC: 16 A resistive/FLA16/LRA72; 240 V AC: 10 A resistive/FLA10/LRA60
Maximum total output for DO4-6Max 10 A total
DisplayLED display, 3 digit
Keypad4 buttons, 2 left and 2 right
Operating conditions0 °C to 55 °C, 93% rH
Storage conditions-40 °C to 85 °C, 93% rH
Measurement range-40 °C to 85 °C with standard sensors
Front protectionIP65
Rear protectionWater and dust protection corresponds to IP31; connector accessibility limits rear rating to IP00
Operating cyclesMore than 175,000 at full load

Frequently asked questions

What is the Danfoss ERC 112 used for?

It is an electronic refrigeration controller with an LED display developed for bottle coolers and commercial fridges and freezers.

Who is this ERC 112 guide intended for?

It is intended for OEMs for programming the ERC 112 and may also be useful for technicians, but it is not intended as a guide for end users.

What access levels does the ERC 112 have?

There are three levels: level 1 for shop access, level 2 for technicians, and level 3 for OEMs.

What tools are used to program the ERC 112?

Programming uses KoolProg software, a USB gateway, a USB programming key, and a docking station.

Download PDF (4.4 MB)