Chint NDKQ-100 Power Transformer Product Leaflet

The Chint NDKQ-100 power transformer leaflet provides specifications, dimensions, installation guidelines, and ordering information for the TDR series.


Chint NDKQ-100 Power Transformer Product Leaflet - cover page
Brand
CHINT
Category
transformer
Document type
Product Leaflet
Language
Chinese
Pages
2
File format
PDF
File size
707 KB
Published
28 September, 2026
Updated
28 September, 2026
MD5 checksum
1F247CF01874E16E82BAC690EBE4F868

About this manual

The NDKQ-100 is part of Chint's TDR series of control transformers, designed for use in CNC machines, office automation equipment, and audio‑visual systems where the supply voltage does not exceed 500 V and the frequency is 50/60 Hz.

The document lists key technical data such as a 100 VA output capacity, 50 Hz frequency, 380 V rated input voltage and 36 V rated output voltage, along with environmental limits (‑5 °C to 40 °C, altitude ≤2000 m, humidity ≤95 %). It also includes ordering details, dimensional drawings, and compliance with standard Q/ZT 285. This manual is written in Chinese.

What's inside

  • Product Name
  • Model
  • Output Capacity
  • Frequency
  • Rated Input Voltage
  • Rated Output Voltage
  • Ordering Information
  • Applicable Range
  • Main Parameters and Technical Performance
  • Structure Features

Specifications

Output capacity100 VA
Frequency50 Hz
Rated input voltage380 V
Rated output voltage36 V
Maximum altitude2000 m
Maximum relative humidity95 %
Standard complianceQ/ZT 285

Frequently asked questions

What is the rated output capacity of the NDKQ-100 transformer?

The NDKQ-100 has a rated output capacity of 100 VA.

What is the maximum altitude for reliable operation?

It can operate reliably at altitudes up to 2000 m.

What input voltage does the NDKQ-100 accept?

The transformer is rated for an input voltage of 380 V.

Download PDF (707 KB)

More CHINT Manuals