Service manual for CAT PUMPS 25PFR plunger pumps covering specifications, lubrication, installation, and valve servicing procedures.
This manual provides service and installation instructions for the CAT PUMPS 25PFR plunger pump, which is designed for 25 frame split manifolds (models 2530, 2531, 2537). It details critical operational requirements such as lubrication with ISO-68 hydraulic oil, proper pump rotation for crosshead lubrication, and motor selection based on flow and pressure requirements. The document emphasizes safety warnings regarding pressure regulation and inlet conditions to prevent pump damage.
| Maximum Specifications | Refer to individual pump Data Sheets |
|---|---|
| Lubrication Oil | CAT PUMPS custom-blend, ISO-68 hydraulic oil |
| Initial Oil Change Interval | 50 hours running period |
| Regular Oil Change Interval | 3 months or 500 hour intervals |
| Crankcase Oil Capacity | 84 oz. (2.5 L) |
The crankcase should be filled with CAT PUMPS custom-blend, ISO-68 hydraulic oil.
Oil should be changed every 3 months or at 500 hour intervals.
The pump was designed for forward rotation to allow optimum lubrication of the crosshead area.
Temperatures above 130°F are permissible, but inlet pressure must be adjusted.