This service manual covers maintenance, disassembly, reassembly, and servicing for the CAT Pumps 35PFR plunger pump.
The document provides a service manual for the CAT Pumps 35PFR series of plunger pumps. It includes critical operational warnings regarding pressure regulation, inlet conditions, and lubrication requirements to ensure safe operation and prevent damage.
Detailed instructions are provided for servicing the valves on various models (including specific procedures for model 3560). The manual outlines steps for disassembly and reassembly of valve plugs, seats, and retainers, along with torque specifications and recommendations for gaskets and lubricants.
| Crankcase Oil Capacity | 4.2 Qts. - 4.0 L |
|---|---|
| Initial Oil Change Interval | 50 hours running period |
| Regular Oil Change Interval | 3 months or 500 hour intervals |
Change the initial fill after 50 hours of running. Thereafter, change the oil every 3 months or at 500-hour intervals.
Mount the pump on a rigid, horizontal surface to permit drainage of crankcase oil and minimize piping stress.
All systems require both a primary pressure regulating device and a secondary pressure safety relief device.