Service manual for CAT Pumps piston pumps in 3, 10, 4 and 25 frames, covering installation, start-up, lubrication, pressure regulation and valve servicing.
This service manual covers CAT Pumps piston pumps in the 3 Frame (280, 281, 290, 291), 10 Frame (621, 623, 820, 821, 825, 1010, 1011, 1015), 4 Frame (331, 333, 335, 430, 431, 435) and 25 Frame (1520, 1521, 1525, 2520, 2521, 2525, 2520C, 4406, 1406, 0406, 4206, 1206, 0206).
Installation and start-up information covers lubrication, pump rotation, pulley and drive selection, mounting, location, inlet and discharge conditions, pressure regulation, nozzles, pumped liquids and storage. Service instructions describe disassembly and reassembly of the valve assemblies, including inspection and replacement of retainers, springs, valves, seats, O-rings and back-up rings.
| Crankcase oil fill by frame | 3FR: 10 oz; 4FR: 21 oz; 5FR: 21 oz; 10FR: 40 oz; 25FR: 84 oz; 60FR: 10 qt |
|---|---|
| Initial oil change interval | After 50 hours of running |
| Routine oil change interval | Every 3 months or 500 hours |
| Drive losses | Approximately 3-5% |
| Inlet pressure adjustment above 130°F | Add 1/2 PSI inlet pressure per each degree F over 130°F |
| Oiler adjustment (25FR, 60FR) | Vertical to start feed; horizontal to stop feed; 45° to drain reservoir |
The specification lists 10FR-40 oz. for a 10 Frame pump.
Change oil every 3 months or 500 hour intervals.
Reverse rotation is acceptable if the crankcase oil level is increased slightly above the center dot to assure adequate lubrication.
Open all valves before starting the system to avoid a deadhead overpressure condition and severe damage to the pump or system.