CAT Pumps Piston Pump Service Manual 3/10/4/25 Frame 280-291 621-1015 331-435 1520-2525C 4406-0206

Service manual for CAT Pumps piston pumps in 3, 10, 4 and 25 frames, covering installation, start-up, lubrication, pressure regulation and valve servicing.


CAT Pumps Piston Pump Service Manual 3/10/4/25 Frame 280-291 621-1015 331-435 1520-2525C 4406-0206 - cover page
Brand
CAT Pumps
Category
Other
Document type
Service Manual
Language
English
Pages
8
File format
PDF
File size
225 KB
Published
09 November, 2026
Updated
09 November, 2026
MD5 checksum
18411427DC7800C7841AAFE5936882C1

About this manual

This service manual covers CAT Pumps piston pumps in the 3 Frame (280, 281, 290, 291), 10 Frame (621, 623, 820, 821, 825, 1010, 1011, 1015), 4 Frame (331, 333, 335, 430, 431, 435) and 25 Frame (1520, 1521, 1525, 2520, 2521, 2525, 2520C, 4406, 1406, 0406, 4206, 1206, 0206).

Installation and start-up information covers lubrication, pump rotation, pulley and drive selection, mounting, location, inlet and discharge conditions, pressure regulation, nozzles, pumped liquids and storage. Service instructions describe disassembly and reassembly of the valve assemblies, including inspection and replacement of retainers, springs, valves, seats, O-rings and back-up rings.

What's inside

  • Specifications
  • Lubrication
  • Pump Rotation
  • Pulley and Drive Selection
  • Mounting and Location
  • Inlet Conditions
  • Discharge Conditions
  • Pressure Regulation
  • Installation and Start-Up Information
  • Servicing the Valve Assemblies

Specifications

Crankcase oil fill by frame3FR: 10 oz; 4FR: 21 oz; 5FR: 21 oz; 10FR: 40 oz; 25FR: 84 oz; 60FR: 10 qt
Initial oil change intervalAfter 50 hours of running
Routine oil change intervalEvery 3 months or 500 hours
Drive lossesApproximately 3-5%
Inlet pressure adjustment above 130°FAdd 1/2 PSI inlet pressure per each degree F over 130°F
Oiler adjustment (25FR, 60FR)Vertical to start feed; horizontal to stop feed; 45° to drain reservoir

Frequently asked questions

What crankcase oil fill does a 10 Frame pump require?

The specification lists 10FR-40 oz. for a 10 Frame pump.

How often should pump oil be changed after the initial fill?

Change oil every 3 months or 500 hour intervals.

Can the pump be run in reverse rotation?

Reverse rotation is acceptable if the crankcase oil level is increased slightly above the center dot to assure adequate lubrication.

What must be done before starting the system?

Open all valves before starting the system to avoid a deadhead overpressure condition and severe damage to the pump or system.