Cat Pumps 9970 Pressure Sensitive Regulating Unloader Data Sheet

Cat Pumps 9970 pressure sensitive regulating unloader data sheet with specifications, installation, operation, disassembly, reassembly and troubleshooting.


Cat Pumps 9970 Pressure Sensitive Regulating Unloader Data Sheet - cover page
Brand
CAT Pumps
Category
Industrial Supply
Document type
Datasheet
Language
English
Pages
4
File format
PDF
File size
358 KB
Published
12 November, 2026
Updated
12 November, 2026
MD5 checksum
15630CE7266DE9D0A5551C993AD32A12

About this manual

The Cat Pumps Model 9970 is a stainless steel pressure sensitive regulating unloader that maintains full system pressure while running in bypass without full load on the pump and offers pump protection against pressure fluctuations and system changes.

This data sheet lists U.S. and metric specifications, selection guidance, installation and operation instructions, pressure adjustment steps, disassembly and reassembly procedures, troubleshooting information, and approximate pressure readings.

What's inside

  • Features
  • Specifications
  • Selection
  • Installation
  • Operation
  • Pressure Adjustment
  • Disassembly
  • Reassembly
  • Troubleshooting
  • Pressure Reading

Specifications

Maximum Flow15.9 gpm (60 lpm)
Pressure Range1160 - 11600 psi (80 - 800 bar)
Operating Temp195° F (90° C)
Weight7.06 lbs. (2.5 kg)
Dimensions7.13 x 4.57 x 1.85" (181 x 116 x 47 mm)

Frequently asked questions

What is the maximum flow of the Cat Pumps 9970 unloader?

The maximum flow is 15.9 gpm (60 lpm).

How do I adjust the pressure on the Cat Pumps 9970 unloader?

Back the unloader off to the lowest setting, then turn the adjusting cap one quarter turn clockwise until the desired pressure is reached.

What should I check if the Cat Pumps 9970 unloader cycles?

Check for a leak downstream of the unloader, a worn O-ring or check valve, air in the system, a worn gun O-ring, or insufficient flow through the unloader.

What minimum bypass flow does the Cat Pumps 9970 unloader require?

A minimum bypass flow of 5% of the unloader rated flow capacity is required for proper performance.