Campbell Scientific TE525 Series Tipping Bucket Rain Gage User Manual

User manual for the Campbell Scientific TE525 Series tipping bucket rain gages, covering setup, ShortCut programming, wiring, specifications, and maintenance.


Campbell Scientific TE525 Series Tipping Bucket Rain Gage User Manual - cover page
Brand
Campbell Scientific
Category
sensor
Document type
User Manual
Language
English
Pages
23
File format
PDF
File size
1.4 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
9A781AB25776902D39214A5B486E84CE

About this manual

The TE525-series tipping bucket rain gages are adaptations of standard National Weather Service tipping bucket rain gages. They funnel rain into a mechanism that tips when filled to a calibrated level; a magnet actuates a switch as the bucket tips, and the momentary switch closure is counted by Campbell Scientific datalogger pulse-counting circuitry. The TE525 and TE525WS measure in 0.01-inch increments, while the TE525MM measures in 0.1-mm increments.

The manual covers initial inspection, Quick Start with ShortCut, overview, specifications, installation and datalogger wiring/programming, operation, and troubleshooting and maintenance. It also includes appendices on importing ShortCut code into CRBasic Editor, an example program, and changing funnels with a different size. It provides information only for CRBasic dataloggers.

What's inside

  • Introduction
  • Precautions
  • Initial inspection
  • Quick Start
  • Overview
  • Specifications
  • Installation
  • Operation
  • Troubleshooting and maintenance
  • Changing funnels with a different size

Specifications

Sensor typeTipping bucket / potted magnetic momentary-contact reed switch
Operating temperature range0 to 50 °C
Storage temperature range–40 to 70 °C
Switch ratings30 VDC at 2 A; 115 VAC at 1 A
Closure time135 ms
Bounce settling time0.75 ms
Accuracy1.0% up to 2 in/hour (50 mm/hr)
Rainfall resolutionTE525 and TE525WS: 0.01 in; TE525MM: 0.1 mm
Cable weight0.1 kg (0.2 lb) per 10 ft
MountingGold anodized aluminum side bracket with adjustable pipe clamps for pole or mast mounting

Frequently asked questions

What is the difference in measurement increments between the TE525, TE525WS, and TE525MM?

The TE525 and TE525WS measure in 0.01-inch increments, while the TE525MM measures in 0.1-mm increments.

Can the CS705 Snowfall Conversion Adapter be used with the TE525 or TE525MM?

No. The CS705 cannot be used with either the TE525 or TE525MM.

What accuracy does the rain gage have?

It has an accuracy of 1.0% up to 2 in/hour (50 mm/hr).

How high should the rain gage be mounted above the ground?

It should be mounted at least 30 cm above the ground and higher than the average snow depth.

Download PDF (1.4 MB)