This manual introduces the usage of SC532 9 pin Peripheral to RS232 Interface
The Campbell Scientific SC532 9-Pin Peripheral to RS232 Interface connects an IBM PC/XT/AT or IBM PS2 compatible computer to certain Campbell Scientific datalogger peripherals. Supported peripherals include Storage Modules and the MD9 Multidrop Interface. The interface provides +5 VDC power to the peripheral and requires a supply voltage of 6 to 17 VDC.
The manual covers function, physical description, specifications, hardware connections, operation, and portable battery power application. Appendices provide SC532 and DTE computer pin descriptions, a schematic, and component location.
| Supply voltage | +6 VDC to 17 VDC |
|---|---|
| Output voltage | 5 VDC + 0.2 VDC |
| Current available to peripheral | 100 mA maximum at 25 deg. C |
| RS232 output levels | +10VDC + 1 VDC / -10VDC + 1 VDC |
| Maximum output impedance | 1100 ohms |
| RS232 input levels | +30V maximum |
| Input impedance | at least 3000 ohms |
| Current drain | 5 mA typical quiescent |
An IBM PC/XT/AT or IBM PS2 compatible computer connects to the SC532 peripheral interface.
It requires a supply voltage of 6 to 17 VDC, or the factory-installed AC adapter plugged into a 110 VAC wall receptacle.
Yes, the AC adapter wire can be cut and spliced to connectors for use with a battery or the AC adapter.