Campbell Scientific SR30 Pyranometer Product Manual

The SR30 is an ISO 9060:2018 spectrally flat Class A (secondary standard) pyranometer manufactured by Hukseflux, featuring recirculating ventilation and heating (RVH™) technology. As a standalone unit, the SR30 is fully compliant with IEC 61724-1 standards, whereas other pyranometers require external ventilation/heating units to be compliant. The SR30 is an ideal instrument for solar resource and photovoltaic (PV) performance monitoring.


Campbell Scientific SR30 Pyranometer Product Manual - cover page
Brand
Campbell Scientific
Category
sensor
Document type
User Manual
Language
English
Pages
18
File format
PDF
File size
4.2 MB
Published
16 November, 2023
Updated
16 November, 2023
MD5 checksum
1CCBAAB75EF0A200658BC77476DE6B56

About this manual

The SR30 is an ISO 9060:2018 spectrally flat Class A (secondary standard) pyranometer manufactured by Hukseflux. It uses recirculating ventilation and heating (RVH™) technology. The manual states the SR30 is fully compliant with IEC 61724-1 as a standalone unit and is intended for solar resource and photovoltaic performance monitoring.

The Campbell Scientific manual covers initial inspection, Quick Start programming with ShortCut, specifications, wiring, CRBasic programming, siting, mounting, operation, the Modbus map, and maintenance and troubleshooting. It also explains importing ShortCut code into CRBasic Editor.

What's inside

  • Quick Start
  • Specifications
  • Installation
  • Wiring
  • Programming
  • Siting
  • Mounting procedure
  • Operation
  • Modbus map
  • Maintenance and troubleshooting

Specifications

ISO classificationSpectrally flat Class A (secondary standard) per ISO 9060:2018
Spectral range285 to 3000 nm
Operating temperature range–40 to 80 °C
Operating voltage range8 to 30 VDC
Power consumption at 12 VDC, standard mode<2.3 W
OutputModbus RS-485
Communications protocolModbus over 2-wire RS-485
Calibration uncertainty<1.2% (k=2)

Frequently asked questions

What ISO classification does the SR30 have?

The SR30 is a spectrally flat Class A (secondary standard) pyranometer under ISO 9060:2018.

What communications protocol and output does the SR30 use?

It uses Modbus over 2-wire RS-485 and provides a Modbus RS-485 output.

What is the default RS-485 address?

The default address is 1; it must be unique and may need to be changed if another sensor on the terminal has the same address.

What is the SR30 operating voltage range?

It operates from 8 to 30 VDC.