Instruction manual for the Campbell Scientific CS210 enclosure relative humidity sensor, including specifications, wiring, programming, and maintenance.
The CS210 Enclosure Relative Humidity Sensor from Campbell Scientific monitors relative humidity inside an equipment enclosure deployed in the field. It contains an Elan HM2000 series precision bulk-polymer relative humidity sensor and is used to schedule desiccant replacement.
This manual covers precautions, initial inspection, QuickStart programming, specifications, mounting, wiring, CRBasic programming, enclosure humidity, and maintenance. It is intended for CRBasic dataloggers and is also compatible with retired Edlog dataloggers.
| Sensor | Elan HM2000 series precision bulk-polymer |
|---|---|
| Relative humidity measurement range | 0 to 100% non-condensing RH |
| Output signal range | 0 to 1.0 V dc |
| Accuracy at 25 °C | ±3% RH (10 to 90% RH); unspecified (0 to 10% RH and 90 to 100% RH) |
| Typical long-term stability | Better than 3% RH per year |
| Response time | 10 s for a 30% to 90% RH step change at 25 °C |
| Operating temperature | 0 to 50 °C |
| Storage temperature | –40 to 80 °C |
| Probe length | 2.5 cm (1.0 in) |
| Probe cross section area | 0.8 cm x 1.3 cm (0.3 in x 0.5 in) |
| Current consumption | <0.5 mA |
| Supply voltage | 5 ± 0.25 V dc |
| Settling time | 10 s |
| Probe cable length | 28 cm (11 in) |
| Compatible dataloggers | Campbell Scientific CRBasic dataloggers: CR200(X) series, CR300 series, CR6 series, CR800 series, CR1000, CR3000, CR5000, and CR9000(X) |
It is compatible with Campbell Scientific CRBasic dataloggers: CR200(X) series, CR300 series, CR6 series, CR800 series, CR1000, CR3000, CR5000, and CR9000(X).
It is also compatible with retired Edlog dataloggers.
The measurement range is 0 to 100% non-condensing RH.
The supply voltage is 5 ± 0.25 V dc.