CAB HYDRO HD.3524E / HD.5024E Hydraulic Swing Gate Operator User Manual

Manual with multilingual labels for CAB HYDRO HD.3524E and HD.5024E hydraulic swing gate operators, covering installation, safety and technical data.


CAB HYDRO HD.3524E / HD.5024E Hydraulic Swing Gate Operator User Manual - cover page
Brand
cab
Category
Automation control Equipment
Document type
User Manual
Language
Italian
Pages
32
File format
PDF
File size
2.8 MB
Published
11 November, 2026
Updated
11 November, 2026
MD5 checksum
1CB2ED8E0D34FEBE33E0510DCFC6156E

About this manual

The document covers the HYDRO HD.3524E, HD.3524E AC, HD.5024E and HD.5024E AC hydraulic actuators for swing gates. It lists model data such as maximum leaf weight and length, useful stroke, reversible and irreversible versions with hydraulic locking, and notes that the HYBRA 24 control panel is required for the encoder slowdown and anti-crush functions.

Installation content includes overall dimensions, installation dimensions, anchoring distances, mechanical stops, oil level checking and electrical connection diagrams. Safety and disposal warnings address qualified installation, safety devices, electrical isolation, original spare parts and end-of-life collection. This manual is written in Italian.

What's inside

  • General information
  • Technical data
  • Preliminary checks
  • Overall dimensions
  • Installation dimensions
  • Mechanical stops
  • Electrical safety
  • Disposal

Specifications

Power supply24 Vdc
Absorbed power240 W
Maximum current5 A
Protection ratingIP55
Operating temperature-20°C/+50°C
Thrust force4000 N
Pump delivery1.4 l/min; 2800 rpm
Rod speed2 cm/s
Useful stroke270 mm (HD.3524E); 390 mm (HD.5024E)
Useful stroke time14 s (HD.3524E); 20 s (HD.5024E)
Duty typeIntensive use
Oil typeBIO OIL

Frequently asked questions

What power supply do the HD.3524E and HD.5024E require?

They are powered by 24 Vdc.

Which control panel is needed for the encoder slowdown and anti-crush functions?

The manual states that the HYBRA 24 control panel must be used for these functions.

Do the HD.3524E and HD.5024E models need an electric lock?

Yes, models without hydraulic locking in opening always require an electric lock.

What is the operating temperature range?

-20°C to +50°C.