Benewake TFmini-S LiDAR Module Product Manual

Product manual for the Benewake TFmini-S single-point ToF LiDAR module, covering specifications, UART/I2C protocol, parameter settings and troubleshooting.


Benewake TFmini-S LiDAR Module Product Manual - cover page
Brand
Benewake
Category
sensor
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.2 MB
Published
16 November, 2026
Updated
16 November, 2026
MD5 checksum
9F035FBC7E915BF895C717B0C4B2243E

About this manual

This manual describes the Benewake TFmini-S LiDAR module, a miniaturized single-point ranging product based on the ToF (time of flight) principle. It presents the measurement principle, main characteristic parameters, repeatability data, distance measurement characteristics, appearance, electrical characteristics and the pin connection of the 4-wire cable.

The document also covers the serial port communication protocol and data output format, I2C data communication and timing, I/O mode, a quick test procedure with required tools, parameter configuration commands, remote upgrading, and a troubleshooting section with causes and remedies plus a Q&A chapter.

What's inside

  • Attentions
  • Product Description
  • Principle of Distance Measurement
  • Main Characteristic Parameters
  • Repeatability
  • Distance Measurement Characteristics
  • Appearance and Structure
  • Electrical Characteristics
  • Line Sequence and Data Communication Protocol
  • Quick Test

Specifications

Operating range0.1 m to 12 m (standard whiteboard with 90% reflectivity, indoor)
Accuracy±6 cm (0.1-6 m); ±1% (6-12 m)
Range resolution1 cm
Measurement unitcm
Frame rate1 to 1000 Hz, adjustable; default 100 Hz
Supply voltage5 V ±0.1 V
Average current≤140 mA
Peak current200 mA
Average power700 mW
Communication levelLVTTL (3.3 V)
Operating temperature0 ℃ to 60 ℃
Storage temperature-20 ℃ to 75 ℃
Detection blind zone0-10 cm, output data unreliable in this zone

Frequently asked questions

Which interfaces does the TFmini-S support?

The product is compatible with both the UART and I2C interface, and the interfaces can be switched by commands.

What is the operating temperature range of the TFmini-S?

It operates between 0 ℃ and 60 ℃, and should not be used outside this range.

How far can the TFmini-S measure a black target?

The operating range when detecting a black target with 10% reflectivity is 0.1-7 m.

Why is there no data output when the LiDAR is connected to the PC software?

Possible causes are that the PC software only supports Windows, a poorly connected TTL-USB board, or a serial port driver that is not correctly installed.

Download PDF (1.2 MB)

More Benewake Manuals


View all Benewake manuals →