This document is the user manual for the Benewake TF02-i, a medium-range LiDAR sensor manufactured by Benewake (Beijing) Photonics Technology Co., Ltd. It covers essential usage precautions, physical interface specifications, and detailed communication protocols. This manual is written in Chinese.
| Operating Temperature | -20°C~60°C |
|---|---|
| Storage Temperature | -30°C~80°C |
| Supply Voltage | 7V~30V |
| Peak Current | 100mA |
| Average Current | ≤70mA@12V |
| Average Power | ≤0.85W@12V |
| Over-voltage Protection | 30V |
| Reverse Polarity Protection | 40V |
| Default RS485 Baud Rate | 115200 |
| Default RS485 Address | 0x01 |
| Default CAN Baud Rate | 250kbps |
Yes, custom parameter configuration is available. Users should consult sales or technical support for details.
The product must be used within a temperature range of -20°C to 60°C.
The device supports a supply voltage of up to 30V.
No, using the product underwater creates a risk of failure.