This is a product manual for the TF-Luna LiDAR module. The module has the following features:
This manual is for the Benewake TF-Luna LiDAR Module and covers cautions, ranging principle and key parameters, appearance and structure, electrical characteristics, functional descriptions and configuration, quick test steps, firmware upgrade, and serial/I2C communication appendices.
The module uses time of flight (TOF) to measure distance. Its stated operating range is 0.2 m to 8 m, with accuracy of ±6 cm from 0.2-3 m and ±2% from 3-8 m, and a field of view of 2°.
| Operating range | 0.2 m to 8 m |
|---|---|
| Accuracy | ±6 cm (0.2-3 m); ±2% (3-8 m) |
| Measurement unit | cm (default) |
| Range resolution | 1 cm |
| Frame rate | 1 to 250 Hz (adjustable) |
| Working temperature | -10°C to 60°C |
| Storage temperature | -20°C to 75°C |
| Ranging dead zone | 20 cm or closer |
| Black target range | 0.2 m to 2.5 m (10% reflectivity) |
| White target range | 0.2 m to 8 m (90% reflectivity) |
| Power supply voltage | 3.7 V to 5.2 V |
The operating range is 0.2 m to 8 m, measured indoors with a standard whiteboard of 90% reflectivity.
Distances of 20 cm or closer are unreliable because the ranging dead zone is 20 cm or closer.
No, the product does not have polarity or over-voltage protection.
The working temperature range is -10°C to 60°C and the storage temperature range is -20°C to 75°C.